Skip to content

Fixing a Piece

Most authoring problems are fixed in the catalog, with no re-export. Open the piece's Edit () settings for the first four. See Editing a piece.

Symptom Fix
A piece faces the wrong way, its outside looking into the room Press Flip facing ()
A corner is turned but the straight walls are fine Turn the corner with Rotation. Try 90, 180 or −90
A piece sits off its grid line Move it with Pivot X / Y / Z
A long piece runs along the wrong axis Set Length axis to Length X or Length Y instead of Auto
The hole in the blue template wall or around a gable window shows its cut edge past the frame Untick Auto under HOLE INSET and raise Width or Height. See Edit settings
Two pillars don't merge They need the same Merged mesh, and their FOOTPRINT areas must come within Attachment Merge Gap. See Adaptive attachments
A storey line shows a thin gap in the cladding Set the pack's Structural Wall Height Cm. See Pack dimensions
A run tiles with a repeating gap The piece isn't an exact multiple of the cell size. See Mesh Rules

Piece settings, added or removed meshes, styles and swatches all undo with Ctrl+Z. Creating, duplicating, deleting or reordering a pack cannot be undone.

When the table isn't enough

HausTools.DumpKit logs the exact size of every piece in the pack. It is the quickest way to catch a mesh that is 290 cm when it should be 3 m. HausTools.DiagnoseKit builds a test corner, a straight run and a 45° run with a window, then writes every size, pivot and placement to a file. See Console Commands.